High Precision Colorimeter with TFT Display – Emissions and Stack

Discover the high-precision color spectrophotometer with advanced features, including TFT display, customizable apertures, and wide wavelength range. 

SKU: EMSBC-235 Category:

Features

  • High configuration of hardware 7 in (178 mm) TFT Colour Capacitive
  • Concave Grating
  • Double Array 256 Image Element CMOS Sensor
  • Long life to span stable LED, UV LED and xenon lamp
  • With reflective and transmissive spectrum, accurate Lab value
  • good to calculate colour formula and do precise colour transmission
  • Auto identify measuring aperture
  • Users also can customize apertures

Technical Specifications

Optical Geometry Reflect di 8°, de 8°(diffused illumination, 8 to degree viewing angle) , SCI (specular component included) or SCE (specular component excluded), Include UV or excluded UV light source, Transmittance di 0°, de 0° (diffuse illumination 0° viewing), SCI (specular component included) or SCE (specular component excluded), Include UV or excluded UV light source, Haze(ASTM D1003),
Conforms to CIE No.15, GB or T 3978, GB 2893, GB or T 18833, ISO7724 or 1, ASTM E1164, DIN5033 Teil7
Integrating Sphere Size 6.06 in (Φ154mm)
Light Source 360 nm to 780 nm, Combined LED Light, 400 nm cut to off light source, 420 nm Cut to off light source, UV Lamp
Spectrophotometric Mode Concave Grating
Sensor 256 Image Element Double Array CMOS Image Sensor
Wavelength Range 360 nm to 780 nm
Wavelength Interval 10 nm
Semi – band Width 10 nm
Measured Reflectance Range 0% to 200%
Specular Component Reflectance SCI and SCE or Transmittance SCI and SCE
Colour Space CIE LAB, XYZ, Yxy, LCh, CIE LUV, Mussel, s to RGB, Hunter Lab, βxy, DIN
Colour Difference Formula ΔE × ab, ΔE × uv, ΔE × 94, ΔE × cmc (2:1), ΔE × cmc (1:1), ΔE × 00, DINΔE 99, ΔE (Hunter)
Other Colorimetric Index WI (ASTM E313, CIE or ISO, AATCC, Hunter, YI (ASTM D1925, ASTM 313), TI (ASTM E313, CIE or ISO), MI (Metamerism Index), Staining Fastness, Colour Fastness, Colour Strength, Opacity, Gardner Index, Pt to Co Index, 555 Index
Observer Angle 2° or 10°
Illuminate D65, A, C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12
Displayed Data Spectrogram or Values, Samples Chromaticity Values, Colour Difference Values or Graph, PASS or FAIL Result, Colour Offset
Measuring Time About 2.4 s (Measure SCI and SCE about 5 s)
Repeatability Spectral reflectance 1 in (Φ25.4 mm) or SCI, Standard deviation within 0.04% (400 nm to 700 nm within 0.04%) Chromaticity value 1 in (Φ25.4 mm )or SCI, Standard deviation within ΔE × ab 0.01 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance 1 in (Φ25.4 mm) or SCI, Standard deviation within 0.05% (400 nm to 700 nm within 0.04%) Chromaticity value 1 in (Φ25.4 mm) or SCI, Standard deviation within ΔE × ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Inter to Instrument Error 1 in (Φ25.4 mm) or SCI, Within ΔE × ab 0.12 (Average for 12 BCRA Series II colour tiles)
Power Supply DC 24 V, 3 A, Power adapter 110 V to 230 V 50 HZ or 60 HZ
Display 7 in (178 mm) TFT colour LCD, Capacitive Touch Screen
Data Port USB and Bluetooth
Data Storage Standard 5000 Pcs, Sample 40000 Pcs (One PCS can include both SCI and SCE)

Altitude

<1.2 mi (<2000 m)

Operating Temperature 32 °F to 104 °F (0 ℃ to 40 ℃)
Storage Environment -4 °F to 122 °F (-20 ℃ to 50 ℃)

Operating Humidity

0% to 85%RH (no condensing)

Storage Humidity

0% to 85%RH (no condensing)
Power Supply DC 24 V, 3 A, Power adapter 110 V to 230 V 50 HZ or 60 HZ
External Size 14.56 in × 11.81 in × 7.87 in (370 mm × 300 mm × 200 mm)
Weight 21.16 lb (9.6 kg)

 