Emissions and Stack Phased Array Flaw Detector

The combination of the Emissions and Stack Phased Array Flaw Detector live total focusing method (TFM) envelope processing, up to 1,024 × 1,024 grid resolution, and vibrant color display make its TFM images stand out with exceptional detail.

SKU: EMSUFD-207 Category:

Overview

The combination of the Emissions and Stack Phased Array Flaw Detector live total focusing method (TFM) envelope processing, up to 1,024 × 1,024 grid resolution, and vibrant color display make its TFM images stand out with exceptional detail. Defects appear sharp and clear with high resolution. The Acoustic Influence Map (AIM) tool provides you with an instant visual model of the sensitivity based on your mode, settings, and simulated reflector. The tool enables you to visualize the effect of a wave set (in TFM mode), see where sensitivity stops, and adjust your scan plan accordingly.

 

Features

  • Detect Early-Stage HTHA
  • Facilitates Flaw Interpretation and Sizing
  • Single time-of-flight diffraction (TOFD) menu for accelerated workflow
  • Improved fast phased array calibration lessens frustration
  • 800% high amplitude range reduces the need to rescan
  • Compatible with Existing Files and Setups
  • Existing probes and scanners
  • MX2/SX data files to compare new data with old and monitor changes through time
  • MX/MX2/SX setups to facilitate procedure compliance

 

Technical Specifications

Category Specification
Size (W × H × D) 13.2 in. × 8.7 in. × 5.9 in. (335 mm × 221 mm × 151 mm)
Weight 12.6 lb (5.7 kg) (with 1 battery)
Onboard Storage 64 GB internal SSD storage,

extendable with external USB drive;

25 GB maximum file size

Storage Devices SDHC™ and SDXC™ cards or most standard USB storage devices
GPS Yes (some regional exceptions)
Alarms 3
Wireless Connection Yes (USB dongle sold separately)
Connectors 1 PA connector, 2 UT channels (2 P/R connectors each)
Number of Groups 8 groups (16:128PR and 32:128PR); 16:64PR offers 2 groups (PA, UT, or TFM) or 2PA + 1 UT
Certifications ISO 18563-1:2015, EN12668-1:2010
Display
Type TFT LCD with resistive touch screen
Size 269 mm (10.6 in.)
Resolution 1280 × 768 pixels
Inputs and Outputs
Ports 2 USB ports (one behind the battery), 1 USB 3.0, HDMI video output, SDHC memory card, Ethernet
Encoder 2-axis encoder line (quadrature or clock/direction), 3rd encoder ready
Digital Input 6 digital inputs, TTL (for acquisition ON/OFF)
Digital Output 5 digital outputs, TTL
Power Output Line 5 V nominal, 1 A (short-circuit protected), and 12 V output at 1 A
External DC Supply 15 VDC to 18 VDC (min. 50 W)
Connector Circular, 2.5 mm pin diameter, center-positive
Battery
Type Lithium-ion battery
Capacity 93 Wh
Number of Batteries 2
Life 5 hours (with 2 batteries; hot-swap capable)
PA/UT Configuration
Effective Digitizing Frequency Up to 100 MHz
Max PRF 20 kHz
Display Refresh Rate A-scan: 60 Hz; S-scan: 20 Hz to 30 Hz
Envelope (Echo Dynamic Mode) Yes: Volume-corrected S-scan (30 Hz)
A-Scan Height Up to 800%
Data Specifications
Max A-Scan Data Points Up to 16,384
Real-Time Averaging PA: 2, 4, 8, 16; UT: 2, 4, 8, 16, 32, 64
Rectification RF, full wave, half wave+, half wave
Filtering PA channel: 3 low-pass, 6 band-pass, and 4 high-pass filters
Video Filtering Smoothing (adjusted to probe frequency range)
Programmable TCG
Number of Points 32 (one TCG curve per focal law)
Range PA (standard): 40 dB per step of 0.1 dB; PA (extended): 65 dB per step of 0.1 dB; UT: 100 dB
Maximum Slope PA (standard): 40 dB/10 ns; PA (extended): 0.1 dB/10 ns; UT: 40 dB/10 ns
Scroll to Top