Technical Specifications
| Dynamic Range | 21 dB and 19 dB |
| Wavelength | 850 and 1300 ±20 nm |
| Pulse Width | 20 ns, 40 ns, 80 ns, 160 ns, 320 ns, 640 ns, 1.28 us, Auto |
| Event Dead Zone | <10 m |
| Attenuation Dead Zone | <20 m |
| Minimum Sampling Spacing | 0.125 m |
| Maximum Number of Samples | 32 k |
| Ranging Precision | ± (1 m + 5 m x 10 m – 5 m x distance + sampling distance) |
| Data Port | Ethernet port |
| Power Consumption | <3 W |
| Input Power | Rated voltage 6 V to 12 V DCripple voltage < 20 m V |
| Dynamic Range | 36 dB |
| Optical Fiber | 9 um and 125 um single-mode optical fiber |
| Connector Converter | FC and PC, FC and UPC, FC and APC |
| Measurement Range | 1 km to 180 km |
| Data Port | Ethernet port |
| Dimensions (Customizable) | 5.63 in x 3.50 in x 0.83 in (143 mm X 89 mm x 21.2 mm) |
| Weight | 0.55 lb. (250 g) |