Emissions And Stack Digital Megohmmeter

This Digital Megohmmeter has 0.01 MΩ insulation resistance resolution, 0 V to 1000 V DC voltage range, and 12.6 V rechargeable battery power supply.

SKU: EMSOHM-133 Category:

Technical specification

Function Insulation resistance test, voltage test
Base conditions 73.4 °F ± 41 °F (23 °C ± 5 °C), below 75% RH
Rated voltage 100 V; 250 V;500 V;1000 V;2500 V;5000 V
Test Voltage rated voltage ×(1 ± 10%)
Insulation Resistance Range (GΩ) 0.01 MΩ to 2000 GΩ
Insulation Resistance Resolution 0.01 MΩ
DC Voltage Range 0 V to 1000 V
DC Voltage Range Resolution 0.1 V
AC Voltage Range 0 V to 750 V
AC Voltage Range 0.1 V
Output short-circuits Current ≥5 mA (5 KV)
Absorption Ratio and Polarization Index Measurement Have
Power Supply 12.6 V rechargeable battery
Backlight Controllable gray screen backlight, suitable for use in dim places
Display mode 4-bit large LCD display, gray screen backlight
LCD display size 4.2 in x 2.5 in (108 mm × 65 mm)
USB interface With USB interface, software monitoring, storage data can be uploaded to the computer, save and print
Communication Line USB communication line 1 PC
Test Line High voltage robs red 9.8 ft (3 m), high voltage test line black 4.9 ft (1.5 m), green 4.9 ft (1.5 m)
Data Storage 500 groups, “FULL” symbol indicates that storage is full
Data Review Data review function: “MR” symbol display
Overflow Display Exceed measurement range overflow function: “OL” symbol display
Alarm Function Alarm when the measured value smaller than the alarm setting value
Power Consumption Standby: 30 mA Max (backlight off)

Turn on backlight: 42 mA Max
Measure:300 mA Max (backlight off)

Battery voltage When the battery voltage is low, low battery symbol will display
Automatic shut-down     automatic shutdown after 15 minutes boot
Insulation Resistance ≥50 MΩ (between Measuring line and housing)
Voltage Withstand AC3 kV or 50 Hz 1 min
Working Temperature and Humidity 14 °F to 122 °F (-10 ℃ to 50 ℃) < 85% RH
Storage Temperature and Humidity 5 °F to 131 °F (-15 ℃ to 55 ℃) <90% RH
Suitable for Safety Regulations IEC 61010-, IEC 1010-2-31, IEC 61557-1,5, IEC 60529 (IP 54) pollution grade 2, CAT Ⅲ 300 V
Instrument size 10.9 in x 8.9 in x 6.02 in (277.2 mm × 227.5 mm × 153 mm)
Instrument weight 5.9 lb (2.72 Kg) (including battery)

Reviews

There are no reviews yet.

Be the first to review “Emissions And Stack Digital Megohmmeter”

Your email address will not be published. Required fields are marked *

Scroll to Top