Emissions And Stack PC Based USB Logic Analyzer

Emissions And Stack pc-based USB logic analyzer LCD Display 2 channels 100 MHz PC based USB logic analyzer storage multimeter oscilloscope.

SKU: EMSPELA-235 Category:

Overview

Emissions And Stack pc-based USB logic analyzer LCD Display 2 channels 100 MHz PC based USB logic analyzer storage multimeter oscilloscope.

 

Features

  • 100 MHz bandwidths
  • 1 GSa or s Real Time sample rate
  • Large 7.0 in (17.7 cm) color display, WVGA (800 × 480)
  • Record length up to 2 M
  • 2 GB SD card and Video Help
  • Trigger mode: edge or pulse width or line
  • selectable video or slop or overtime etc.
  • USB host and device connectivity, standard
  • Multiple automatic measurements
  • Four math functions, including FFTs standard
  • Provides software for PC real-time analysis
  • VGA Optional

 

Technical Specification

Bandwidth 200 MHz, 100 MHz, 60 MHz
Real-time Sample Rate 1 GSa or s
Equivalent Sample Rate 25 GSa or s
Record Length (Sample Points) Single-channel: Maximum 2 M; Dual-channel: Maximum 1 M (4 K,16 K,40 K optional)
SEC or DIV Range 4 ns or div-40 S or div (in a 2, 4, 8 sequence)
Delay Time Accuracy 500 PS
A or D Converter 8-bit resolution, each channel sampled simultaneously
VOLTS or DIV Range 2 mV div to 5 V or div at input BNC
Position Range ±50 V (5 V or div), ±40 V (2 V or div to 500 mV or div), 2 V (200 mV or div to 50 mV or div) ±400 mV (20 mV or div to 2 mV or div)
Rise Time at BNC ≤1.7 ns, ≤3.5 ns, ≤5.8ns
DC Gain Accuracy ±4% for Sample or Average acquisition mode, 5 mV or div to 2 mV or div
±3% for Sample or Average acquisition mode, 5 V or div to 10 mV or div
Trigger Sensitivity
(Edge Trigger Type)
DC: CH1 or CH2(Typical) 1 div from DC to 10 MHz;1.5 div from 10 MHz to Full
EXT(Typical) 200 mV from DC to 40 MHz
EXT or 5(Typical) 1 V from DC to 40 MHz
AC: Attenuates signals below 10 Hz
HF Reject: Attenuates signals above 80 kHz
LF Reject: Attenuates signals below 150 kHz
Noise Reject: Reduces trigger sensitivity
Trigger Level Range CH1, CH2: ±8 divisions from center of screen
EXT: ±1.2 V EXT or 5: ±6 V
Trigger Level Accuracy,
typical (Accuracy is for signals having risen and fall times ≥20 ns)
CH1, CH2: ± (0.3div × V or div) (within ±4 divisions from center of screen)
EXT: ± (6% of setting + 40 mV)
EXTor5: ± (6% of setting + 200 mV)
Holdoff Range 100 ns to 10 ns
Edge Trigger on the rising or falling edge
Pulse Width Trigger (when >, <, =, ≠) on positive or negative pulses
Pulse Width Range: 20 ns to 10ns
Video Trigger on an NTSC, PAL, or SECAM standard video signal
Line Range: 1 to 525 (NTSC), 1 to 625 (PAL or SECAM)
Slope Trigger (when >, <, =, ≠) on a positive or negative slope
Set Time: 20 ns to 10ns
Overtime from the rising or falling edge
Set Time: 20 s to 10 s
Alternate Internal trigger on edge, pulse width, video or slope
Resolution 800 × 480 dots
Contrast 16 gears, with the progress bar to show adjustment
Interface USB host and USB slave
Voltage 100 VACRMS to 120VACRMS (±10%), 45 Hz to 440 Hz, CAT II
120 VACRMS to 240 VACRMS (±10%), 45 Hz to 66 Hz, CAT II
Power <30 W
Fuse 2A, T rating, 250 V
Size 12.3 in × 4.2 in × 5.5 in (313 mm × 108 mm × 142 mm) (L × H × W)
Weight 0.9 lb (2.08 kg)