Emissions And Stack LCD Display Benchtop Logic Analyzer

This LCD Display Benchtop Logic Analyzer has bandwidth of 60 MHz to 200 MHz, record length of 2 M and pulse width range of 20 ns to 10 s.

SKU: EMSBLA-205 Category:

Features

  • 200 MHz or 100 MHz or 60 MHz bandwidth
  • 1 GSa/s Real Time sample rate
  • Large (7.0 in (17.7 cm)) color display, WVGA (800 x 480)
  • Record length up to 2 M
  • Trigger mode edge or pulse width or line selectable video or slop
  • USB host and device connectivity, standard
  • Multiple automatic measurements
  • Four math functions, including FFTs standard

 

Technical Specifications

Bandwidth 200 MHz
Real-time Sample Rate 1 GSa or s
Equivalent Sample Rate 25 GSa or s
Inputs Coupling AC, DC, GND
Inputs Impedance 1 MΩ ± 2 %, 20 pF ± 3 pF
Probe Attenuation 1 X, 10 X
Supported Probe Attenuation Factor 1 X, 10 X, 100 X, 1000 X
Sample Rate Range 500 MS or s to 1 GS or s
Waveform Interpolation (sin x) or x
Sample Rate and
Delay Time Accuracy
± 50 ppm (at over any ≥ 1 ms time interval)
Delta Time Measurement Accuracy
(Full Bandwidth)
Single-shot, Normal mode ± (1 sample interval +100 ppm × reading + 0.6 ns),
>16 averages ± (1 sample interval + 100 ppm × reading + 0.4 ns), Sample interval = s or div ÷ 200
Offset Range 2 mV or div to 20 mV or div, ± 400 mV, 50 mV or div to 200 mV or div, ± 2 V
500 mV or div to 2 V or div, ± 40 V, 5 V or div to 10 V or div, ± 50 V
SEC or DIV Range 4 nS or div to 40 S or div
Rise Time at BNC (typical) 1.8 ns
Vertical resolution 8 bit resolution, each channel sampled simultaneously
Position Range 2 ns or div to 8 ns or div, (-8 div x s or div) to 20 ms
Math +, -, *, /, FFT
FFT Windows Hanning, Flat top, Rectangular, Bartlett, Blackman, 1024 sample point
Bandwidth Limit 20 MHz
Low Frequency Response (-3db) ≤ 10 Hz at BNC
DC Gain Accuracy ± 3 % for Normal or Average acquisition mode, 10 V or div to 10 mV or div, ± 4 % for Normal or Average acquisition mode, 5 mV or div to 2 mV or div
Volts measurement repeatability,
Average Acquisition Mode
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative
Trigger Source CH1, CH2, EXT, EXT/5, AC Line
Trigger Modes Auto, Normal, Single
Coupling Type DC, AC, Noise Reject, HF Reject, LF Reject
Trigger Level Range CH1 or CH2 ± 8 divisions from centre of screen, EXT ± 1.2 V, EXT/5 ± 6 V
Set Level to 50 %(typical) Operates with input signals ≥50 Hz
Video Trigger Type CH1, CH2 Peak-to-peak amplitude of 2 divisions, EXT 400 mV, EXT/5 2 V
Signal Formats and Field Rates, Video Trigger Type Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Hold off Range 100 ns to 10 s
Pulse Width Trigger Mode Trigger when (<, >, =, or ≠), Positive pulse or Negative pulse
Pulse Width Range 20 ns to 10 s
Slope Trigger Mode Trigger when (<, >, =, or ≠); Positive slope or Negative slope
Time Range 20 ns to 10 s