Emissions And Stack High Precision LCR Meter

This High Precision LCR Meter has a temperature range of 32 °F to 104 °F (0 °C to 40 °C), humidity of ≤ 90 % RH, frequency of up to 63 Hz.

SKU: EMSLCR-139 Category:

Features

  • 3-inchTFT LCD Display
  • Maximum test frequency of 1MHz
  • Integrated transformer test function and balance test function
  • Maximum test speed: 13 ms/time
  • Automatic level control function for V and I
  • Test signal level monitor function for V and I
  • Included interior DC bias source
  • External DC bias source of large current
  • 10-point list sweep function
  • Selectable internal resistance of 30 Ω, 50 Ω. 100 Ω
  • Internal storage and external USD disk for file storage directly
  • RS232C, USB, LAN, HANDLER, GPIB, DCI interface

Technical Specifications

Display 480 x RGB x 272 4.3 in TFT LCD display
Frequency of Test Signal
  20 Hz to 300 kHz
  20 Hz to 500 kHz
  20 Hz to 1 MHz
Minimum Resolution 10 MHz, 4-digit frequency input
Accuracy 0.01 %
AC Level
Voltage Range of Test Signal 10 mV to 2 Vrms
Minimum Resolution of Voltage 100 μV, 3-digit input
Accuracy ALC ON 10 % x set voltage + 2 mV
ALC OFF 6 % x set voltage + 2 mV
Current Range of Test Signal 100 μA to 20 mA
Minimum Resolution of Current 1 μA, 3-digit input
Accuracy ALC ON 10 % x set current + 20 μA
ALC OFF 6 % x set voltage + 20 μA
DC Bias Voltage Source
Voltage or Current range 0 V to ± 5 V or 0 mA to ± 50 mA
Resolution 0.5 mV or 5 μA
Voltage Accuracy 1 % x set voltage + 5 mV
ISO ON Be used for the bias test of inductance and transformer
AC Source Impedance ISO ON 100 Ω
ISO OFF 30 Ω,50 Ω,100 Ω selectable
DCR Source Impedance 30 Ω,50 Ω,100 Ω selectable
Test Parameters of LCR Z, Y, C, L, X, B, R, G, D, Q, θ, DCR, Vdc-Idc
Parameter Display of Test Page One set of main or sub parameter, 10-point list sweep
Test Parameters of Transformer DCR 1 (primary, 2-terminal),
DCR 2 (secondary, 2-terminal),
M (mutual inductance), N, 1/N,
Phase, Lk (leakage inductance),
C (primary, secondary capacitance), balance test
Basic Accuracy LCR test parameter 0.05 %
N 0.10 %
Calibration Warm-up time ≥ 30 s
Environment temperature: 73.4 °F to 41 °F (23 °C to 5 °C)
Signal voltage: 0.3 Vrms to 1 Vrms
Zeroing: After OPEN or SHORT
Length of test cable: 0 mi (0 m)
Measurement time (≥ 10 kHz) Fast: 13 ms / time
Medium: 67 ms / time
Slow:187 ms / time
Plus the refresh time of display
character
Display Range of
LCR Parameter
Z, R, X, DCR 0.00001 Ω to 99.9999 MΩ
Y, G, B 0.00001 μs to 99.9999 s
C 0.00001 pF to 9.99999 F
L 0.00001 μH to 99.9999 kH
D 0.00001 to 9.99999
Q 0.00001 to 99999.9
Θ (DEG) -179.999 º to 179.999 º
Θ (RAD) -3.14159 to 3.14159
Δ % -999.999 % to 999.999 %
Equivalent Circuit Serial, Parallel
Range Mode Auto, Hold
Trigger Mode Internal, Manual, External, Bus
Average Times 1 to 255
Calibration Function Open, short calibration with full frequency or dot frequency, Load
Math Operation Direct reading, ΔABS, Δ%
Delay Time Setup 0-999, minimum resolution: 100 us
Comparator 10-bin sorting, BIN1-BIN9, NG, AUX
Bin counter
PASS or FAIL on front panel, LED indication
List Sweep 10 points list sweep
Frequency, AC voltage or current, internal or external bias voltage or current can be swept;
Each sweep point can be sorted separately;
Internal Nonvolatile Memory 100 sets of LCRZ setting files
201 times test results
External USB Memory GIF files
LCRZ setting files
Test data can be stored via USB memory directly.
Interface I/O interface HANDLER on rear panel
SCI USB, RS232C
PCI GPIB (optional)
NI LAN
Memory interface USB HOST (front panel)
Bias current source
control interface
DCI
External DC bias current source can be controlled by using DCI interface.
The maximum bias current can reach 120A.
Option. Only choose either DCI or GPIB
General Specifications
Operating Temperature and Humidity 32 °F to 104 °F (0 °C to 40 °C), ≤ 90 % RH
Power Supply Voltage 99 V to 121 V, 198 V to 242 V AC
Frequency 47 Hz to 63 Hz
Consumption Max. 80 VA
Dimension (W x H x D) 11 in x 3.46 in x 14.56 in (280 mm x 88 mm x 370 mm), with no sheath
14.52 in x 4.25 in x 16.06 in (369 mm x 108 mm x 408 mm), with sheath
Weight Approx. 11 lb (5 kg)

Reviews

There are no reviews yet.

Be the first to review “Emissions And Stack High Precision LCR Meter”

Your email address will not be published. Required fields are marked *

Scroll to Top