Emissions And Stack LCR Bridge Meter Continuous Adjustable Frequency

Emissions And Stack LCR bridge meter Continuous adjustable frequency is a compact bench type professional LCR meter with 4.3 in (10.92 cm) TFT LCD.

SKU: EMSLCR-196 Category:

Overview

Emissions And Stack LCR bridge meter Continuous adjustable frequency is a compact bench type professional LCR meter with 4.3 in (10.92 cm) TFT LCD. The digital LCR meter test frequency ranges from 100 kHz, 200 kHz, 300 kHz and 500 kHz. The basic test accuracy is 0.05 %. The LCR meter digital can be used for test passive components, such as incoming inspection, the production and sorting of passive components.

Features

  • 32 – bit core processor
  • 5 – digit 4.3 in (10.92 cm) TFT LCD display
  • 4 signal source output impedance: 30 Ω, 100 Ω, 10 or 100, or 10 CC
  • List mode function, 10 steps
  • 100 sets memories for internal storage or save
  • 500 memories for U disk storage or save, supports FAT 16 and FAT 32 files
  • Save the last parameter settings before powering off
  • Standard interface: RS – 232, HANDLER, USB HOST, USB Device, FOOT C

 

Technical specifications

Min frequency step 0.1 MHz
Basic accuracy 0.05 %
Equivalent circuit Series, Parallel
Mathematical function Absolute Deviation and Percentage Deviation
Range mode Auto, Hold, Manual Selection
Trigger mode Internal, Manual, External, BUS
Measurement speed Fast: max. 75, Medium: 12, Slow: 3 (times or second) (≥1 kHz)
Average times 1 to 255
Delay time 0 to 60 s, step 1 ms
Calibration function Open circuit, short circuit, Load
Display mode Direct, Δ, Δ %, V or I (monitoring test voltage and current)
Display 6 digit 4.3 – in LCD display (480 x 272 RBG5)
List Mode 10 steps
Output impedance 30 Ω, 100 Ω, 10 or 100, 10 or CC
Test level and accuracy  Normal: 5 mV to 2 VRMS, accuracy 10%, Min step 1 mV, Max test current 20 mA
Constant level: 5 mV to 1 VRMS, accuracy 6 %, Min step 1 mV
DC bias source 0 V, 1.5 V, 2 V Accuracy 1 %
|Z|, R, X 0.01 mΩ to 99.99 MΩ
DCR 0.001 mΩ to 99.99 MΩ
|Y|, G, B 0.00001 µS to 99.99 S
C 0.00001 pF to 9.99 F
L 0.00001 µH to 99.99kH
D 0.00001 to 9.99
Q 0.00001 to 99999.9
θ (DEG) -179.99 º to 179.99 º
θ (RAD) -3.14 to 3.14
Δ% -999.99 % to 999.99 %
Comparator 10 bins (9 pass 1 fail) and 1 AUX bin
Memory 100 sets memories for internal parameter settings storage or save
500 sets for U disk parameter settings storage or save
Standard interface Standard: RS232, USB HOST, HANDLER, EARPHONE, PEDAL interfaces
Optional interface GPIB
Operating environment 32 °F (0 °C) to 104 °F (40 °C), ≤ 80 % RH
Power source 110 V or 220 V± 10 %, 47 to 63 Hz
Power consumption ≤ 50 VA
Accessories 4-terminal Kelvin test clip leads, RS232 cable, power cord, operation manual
Dimensions 10.43 in x 3.93 in x 13.38 in (265 mm x 100 mm x 340 mm)
Weight 9.92 lb (4.5 kg)

Reviews

There are no reviews yet.

Be the first to review “Emissions And Stack LCR Bridge Meter Continuous Adjustable Frequency”

Your email address will not be published. Required fields are marked *

Scroll to Top