Overview
Emissions And Stack’s high precision laboratory LCR meter with frequency sweep function is a reliable device designed for accurate measurement of inductance, capacitance, resistance, and impedance. It offers a wide test frequency range from 50 Hz to 100 kHz, with selectable points for flexibility in different testing scenarios. With a basic accuracy of 0.05% and six-digit resolution, this device ensures stable and precise measurements suitable for laboratories, production facilities, and research environments. Its 4.3-inch TFT LCD provides clear results and an intuitive interface, while advanced correction modes such as Open, Short, and Load improve testing accuracy.
Features
- Wide test frequency ranges from 50 Hz to 100 kHz
- High measurement accuracy of 0.05%
- 3-inch TFT LCD with user-friendly display
- Advanced correction modes (Open, Short, Load)
- Supports multiple trigger modes and averaging functions
- Six-digit resolution for precise readings
- Frequency sweep and comparator functions included
- Multiple standard interfaces with SCPI compatibility
Technical Specifications
| Basic Measurement Accuracy | LCRZ: 0.05% DCR: 0.1% |
| Test Frequency Range | 50 Hz to 100 kHz, 34 points (50 Hz, 60 Hz, 75 Hz, 100 Hz, 120 Hz, 150 Hz, 200 Hz, 250 Hz, 300 Hz, 400 Hz, 500 Hz, 600 Hz, 750 Hz; 1 kHz, 1.2 kHz, 1.5 kHz, 2 kHz, 2.5 kHz, 3 kHz, 4 kHz, 5 kHz, 6 kHz, 7.5 kHz, 10 kHz, 12 kHz, 15 kHz, 20 kHz, 25 kHz, 30 kHz, 40 kHz, 50 kHz, 60 kHz, 75 kHz, 100 kHz) |
| AC Test Signal Level | Resolution: 10mV, Accuracy: 10% x setting voltage+2mV Current: 100 µA to 20 mA RMS Resolution: 0.1 mA |
| DCR Test Signal Level | 1 V DC |
| Resolution | 6 digits |
| Test Parameters | Inductance, Capacitance, Resistance, Impedance, DC Resistance, Quality Factor, Dissipation Factor, Phase Angle, |
| Display Ranges | Z, R, X: 0.00001 Ω to 99.9999 MΩ; Y, G, B: 0.00001 µs to 99.9999 s; C: 0.00001 pF to 9.99999 F; L: 0.00001 µH to 99.9999 kH; D: 0.00001 to 9.99999; Q: 0.00001 to 99999.9; θ (deg): -179.999° to +179.999°; θ (rad): -3.14159 to +3.14159; Δ%: -999.999% to +999.999% |
| Measurement Speed (≥ 10 kHz) | Fast: 75 meas/s (13 ms), Medium: 11 meas/s (90 ms), Slow: 2.7 meas/s (370 ms) |
| Equivalent Circuit | Series, Parallel |
| Range Mode | Auto, Hold |
| Trigger Modes | Internal, Manual, External, Bus |
| Trigger Delay Time | 0 s to 60.000 s (1 ms steps) |
| Step Delay Time | 0 s to 60.000 s (1 ms steps) |
| Average Count | 1 to 255 |
| Correction Modes | Open, Short, Load |
| Math Operations | Direct reading, ΔABS, Δ% |
| List Sweep | 10 points; Frequency, AC voltage or AC current, internal or external bias; Each sweep point sortable |
| Comparator Function | 10 bins (BIN1 to BIN9, NG, AUX); PASS or FAILLED |
| Internal Storage | 100 instrument settings, 201 test results |
| USB Storage | Settings, measurement results (CSV), screenshots (GIF) |
| Interfaces | Control: HANDLER; Communication: USB Host, USB Device, RS-232C, RS-485 (optional), GPIB (optional) |
| Display | 4.3 in TFT LCD |
| Dimensions | 18.50 in × 14.57 in × 10.24 in (47 cm × 37 cm × 26 cm) |
| Weight | 19.84 lb (9 kg) |







Reviews