High Precision Laboratory LCR Meter with Frequency Sweep Function – Emissions And Stack

Emissions And Stack’s high precision laboratory LCR meter with frequency sweep function is a reliable device designed for accurate measurement of inductance, capacitance, resistance, and impedance.

SKU: EMSLLCR-103 Category:

Overview

Emissions And Stack’s high precision laboratory LCR meter with frequency sweep function is a reliable device designed for accurate measurement of inductance, capacitance, resistance, and impedance. It offers a wide test frequency range from 50 Hz to 100 kHz, with selectable points for flexibility in different testing scenarios. With a basic accuracy of 0.05% and six-digit resolution, this device ensures stable and precise measurements suitable for laboratories, production facilities, and research environments. Its 4.3-inch TFT LCD provides clear results and an intuitive interface, while advanced correction modes such as Open, Short, and Load improve testing accuracy.

 

Features

  • Wide test frequency ranges from 50 Hz to 100 kHz
  • High measurement accuracy of 0.05%
  • 3-inch TFT LCD with user-friendly display
  • Advanced correction modes (Open, Short, Load)
  • Supports multiple trigger modes and averaging functions
  • Six-digit resolution for precise readings
  • Frequency sweep and comparator functions included
  • Multiple standard interfaces with SCPI compatibility

 

Technical Specifications

Basic Measurement Accuracy LCRZ: 0.05%
DCR: 0.1%
Test Frequency Range 50 Hz to 100 kHz, 34 points (50 Hz, 60 Hz, 75 Hz, 100 Hz, 120 Hz, 150 Hz, 200 Hz, 250 Hz, 300 Hz, 400 Hz, 500 Hz, 600 Hz, 750 Hz; 1 kHz, 1.2 kHz, 1.5 kHz, 2 kHz, 2.5 kHz, 3 kHz, 4 kHz, 5 kHz, 6 kHz, 7.5 kHz, 10 kHz, 12 kHz, 15 kHz, 20 kHz, 25 kHz, 30 kHz, 40 kHz, 50 kHz, 60 kHz, 75 kHz, 100 kHz)
AC Test Signal Level Resolution: 10mV, Accuracy: 10% x setting voltage+2mV
Current: 100 µA to 20 mA RMS
Resolution: 0.1 mA
DCR Test Signal Level 1 V DC
Resolution 6 digits
Test Parameters Inductance, Capacitance, Resistance, Impedance, DC Resistance, Quality Factor, Dissipation Factor, Phase Angle,
Display Ranges Z, R, X: 0.00001 Ω to 99.9999 MΩ;
Y, G, B: 0.00001 µs to 99.9999 s;
C: 0.00001 pF to 9.99999 F;
L: 0.00001 µH to 99.9999 kH;
D: 0.00001 to 9.99999;
Q: 0.00001 to 99999.9;
θ (deg): -179.999° to +179.999°;
θ (rad): -3.14159 to +3.14159;
Δ%: -999.999% to +999.999%
Measurement Speed (≥ 10 kHz) Fast: 75 meas/s (13 ms),
Medium: 11 meas/s (90 ms),
Slow: 2.7 meas/s (370 ms)
Equivalent Circuit Series, Parallel
Range Mode Auto, Hold
Trigger Modes Internal, Manual, External, Bus
Trigger Delay Time 0 s to 60.000 s (1 ms steps)
Step Delay Time 0 s to 60.000 s (1 ms steps)
Average Count 1 to 255
Correction Modes Open, Short, Load
Math Operations Direct reading, ΔABS, Δ%
List Sweep 10 points; Frequency, AC voltage or AC current, internal or external bias; Each sweep point sortable
Comparator Function 10 bins (BIN1 to BIN9, NG, AUX); PASS or FAILLED
Internal Storage 100 instrument settings, 201 test results
USB Storage Settings, measurement results (CSV), screenshots (GIF)
Interfaces Control: HANDLER; Communication: USB Host, USB Device, RS-232C, RS-485 (optional), GPIB (optional)
Display 4.3 in TFT LCD
Dimensions 18.50 in × 14.57 in × 10.24 in (47 cm × 37 cm × 26 cm)
Weight 19.84 lb (9 kg)

Reviews

There are no reviews yet.

Be the first to review “High Precision Laboratory LCR Meter with Frequency Sweep Function – Emissions And Stack”

Your email address will not be published. Required fields are marked *

Scroll to Top