Emissions And Stack Function Generators

This Function Generators has sample rate of 1 GSa/s, bandwidth of 200 MHz, 100 MHz and 70 MHz and rise time at BNC of 1.8 ns, 3.5 ns and 5 ns.

SKU: EMSFG-182 Category:

Features

  • 2 Channel Digital Oscilloscope + 1
  • Channel Arbitrary or Function
  • Waveform Generator +
  • Synchronizing Signal + External Trigger
  • The Keys for oscilloscope and waveform
  • Generator is separated for convenient
  • Operate it simultaneously
  • Oscilloscope: 1 GSa/s
  • Sample Rate,100 MHz Bandwidth
  • 20 kinds of auto measurement functions
  • Powerful Trigger Function: Edge, Video,
  • Pulse, Slope, Over time, Alternative;
  • Arbitrary or Function Waveform
  • Generator: 25 MHz, 12 bits resolution
  • Support SD card, VGA function (optional);
  • Integrated USB Host,
  • Support USB disk storage,
  • USB interface or SD card system update

 

Technical Specifications

Sample Rate Sampling Rate Range: 1 GSa/s
Equivalent Sample Rate: 25 GSa/s
Acquisition Modes
Normal Normal data only
Peak Detect High-frequency and random glitch capture
Average Waveform Average, selectable 4,8,16,32,64,128
Inputs Coupling AC, DC, GND
Inputs Impendence 1 MΩ ±2 % 20 pF±3 pF
Probe Attenuation 1 x, 10 x
Supported Probe Attenuation Factor 1 x, 10 x, 100 x, 1000 x
Maximum Input Voltage CAT I and CAT II: 300 VRMS (10×)
CAT III: 150 VRMS (1×);
Installation Category II: derate at 20dB/decade above 100 kHz to 13 V peak AC at 3 MHz x and above. For non-sinusoidal waveforms, peak
Value must be less than 450 V. Excursion above 300 V should be of less than 100 ms duration. RMS signal level including all DC
Components removed through AC coupling must be limited to 300 V. If these values are exceeded, damage to the oscilloscope may occur.
Sample Rate Range 1 GS/s
Waveform Interpolation (sin x) or x
Record Length 40 K
SEC or DIV Range 2 ns or div to 40 s or div
Sample Rate and Delay Time Accuracy ±50 ppm (at over any ≥1 ms time interval)
Position Range 2 ns or div to 8 ns or div; 

20 ns or div to 80 us or div; (-8 div x s or div) to 40 ms;

(-8 div x s or div) to 20 ms;

200 us or div to 40 s or div; (-8 div x s or div) to 400 s

Delta Time Measurement Accuracy Single shot, Normal mode: ± (1 sample interval +100 ppm × reading + 0.6 ns);
(Full Bandwidth) >16 averages: ± (1 sample interval + 100 ppm × reading + 0.4 ns);
Sample interval = s or div ÷ 200
Vertical
Vertical Resolution 8-bit resolution, all channel sampled simultaneously
Position Range 2 mV or div to 10 V or div
Bandwidth 200 MHz,100 MHz,70 MHz
Rise Time at BNC (typical) 1.8 ns,3.5 ns, 5 ns
Offset Range 2 mV or div to 20 mV or div, ±400 mV; 50 mV or div to 200 mV or div, ±1 V
500 mV or div to 2 V or div, ±40 V; 5 V or div to 10 V or div, ±50 V
Math +, -, x, or FFT
FFT Windows: Hanning, Flattop, Rectangular, Bartlett, Blackman;
1024 sample point
Bandwidth Limit 20 MHz
Low Frequency Response (3db) ≤10 Hz at BNC
DC Gain Accuracy ±3 % for Normal or Average acquisition mode, 10 V or div to 10 mV or div;
±4 % for Normal or Average acquisition mode, 5 mV or div to 2 mV or div
DC Measurement Accuracy, When vertical displacement is zero, and N ≥16: ± (3 % × reading + 0.1 div + 1 mV) only 10mV/div or greater is selected;
Average Acquisition Mode When vertical displacement is not zero, and N≥16: ± [3 % × (reading + vertical position) + 1% of vertical position+ 0.2 div]; Add
2 mV for settings from 2 mV or div to 200 mV or div; add 50 mV for settings from 200 mV or div to 10 V or div
Volts Measurement Repeatability, Average Acquisition Mode Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions

Reviews

There are no reviews yet.

Be the first to review “Emissions And Stack Function Generators”

Your email address will not be published. Required fields are marked *