Emissions And Stack precision digital LCR tester possesses a higher test speed, a more comprehensive analysis function and friendly human-computer interactive experience by adopting the latest high-speed processor and a new software system. Well-designed measuring circuit and optimized algorithms further enhance the test stability of low-D capacitance and high-Q inductors. The instrument is provided with 10 V AC test level, 10 V or 100 mA bias current and standalone 10 V or 50 mA DC current, making it convenient for applying in the test of all kinds of active or passive devices. Main or sub parameters display, enhanced display system design, 150-points list sweep and graphical analysis capabilities of multiple parameters meet the most application requirements of customers. Thanks to the application of a new generation of processors, the instrument has a more powerful data processing capability. The test results can be easily stored on the U disk or uploaded to the upper PC or network through multiple interfaces, promoting test automation and test efficiency. The test frequency is 20 Hz to 300 KHz, 20 Hz to 500 KHz and 20 Hz to 1 MHz. The instrument has a test accuracy of 0.05% and highest test speed of 9 ms/time. Being equipped with multiple interfaces of HANDLER, USB, LAN, RS232C, DCI, GPIB (option) as well as rich resources, the instrument will bring excellent cost performance experience for customers. It is completely appropriate for test requirements of all kinds of industrial and military standards.

 

Technical Specifications

Frequency of test signal 20 Hz to 1 MHz
Minimum resolution 1 MHz, 5-digit frequency input
Accuracy 0.01%
Display 800 × RGB × 480, 7 in (17.78 cm) TFT LCD display
AC Level Voltage range of test signal 5 mV to 10 VRMS
Minimum resolution of voltage 100 μV, 3-digit input
Accuracy ALC ON 10% x set voltage + 2 mV
ALC OFF 6% x set voltage + 2 mV
Current range of test signal 50 μA to 100 mA
Minimum resolution of current 1 μA, 3-digit input
Accuracy ALC ON 10% x set current + 20 μA
ALC OFF 6% x set voltage + 20 μA
DC bias voltage source Voltage or Current range 0 V to ±10 V or 0 mA to ±100 mA
Resolution 0.5 mV or 5 μA
Voltage accuracy 1% x set voltage + 5 mV
ISO ON Be used for the bias test of inductance and transformer
AC Source impedance ISO ON 100 Ω
ISO OFF 30 Ω, 50 Ω, 100 Ω selectable
DCR Source impedance 30 Ω, 50 Ω, 100 Ω selectable
DC Independent voltage source Voltage or current range 0 V to ±10 V or 0 mA to ±50 mA
Resolution 0.5 mV or 5 μA
Voltage accuracy 1% x set voltage + 5 mV
Output resistance 100 Ω
Test parameters of LCR |Z|, Y|, C, L, X, B, R, G, D, Q, θ, DCR, Vdc to Idc
Parameter display of test page Two sets of main or sub parameters, the second set can be set as ON or OFFThere can be 10 pages of list sweep and 15 points per page at
most

Multiple parameters continuous sweep graphical analysis.

Basic accuracy LCR test parameter 0.05%
Calibration Warm-up time less than 30 secondsSignal voltage: 0.3 VRMS to 1 VRMS

Zeroing: After OPEN or SHORT

Display range of LCR parameter Z, R, X, DCR 0.00001 Ω to 99.99 MΩ
|Y|, G, B 0.00001 μs to 99.99 s
C 0.00001 pF to 9.99 F
L 0.00001 μH to 99.99 kH
D 0.00001 to 9.99
Q 0.00001 to 99999.9
θ(DEG) -179.99º to 179.99º
θ(RAD) -3.14 to 3.14
Δ% -999.99% to 999.99%
Equivalent circuit Serial, Parallel
Range mode Auto, Hold
Trigger mode Internal, Manual, External, Bus
Average times 1 to 256
Calibration function Open, short calibration with full frequency or dot frequency, Load
Math operation Direct reading, ΔABS, Δ%
Delay time setup 0 to 999, minimum resolution: 100 us
Comparator 10-bin sorting, BIN1-BIN9, NG, AUX
Bin counter
PASS or FAIL on front panel, LED indication
List sweep 201-point list sweep functionList sweep of frequency, AC voltage or current, internal or external DC bias voltage or current and
independent DC source voltage can be performed on each page

Each sweep point can be sorted separately

Graphical analysis Graph scanning and analysis of frequency, AC level and DC bias can be performedSet the sweep start point, end point and each sweep point display the maximum value, minimum value and read any of the chosen sweep point scanning graphs can be stored into internal or external USB memory
Internal nonvolatile memory 100 sets of LCRZ setting files memory 201 times test results 10 sets of GIF image, CSV data files
External USB memory GIF image, CSV data filesLCRZ setting files memory

Test data can be stored via USB