Emissions and Stack Concrete Flaw Detector

Emissions and Stack concrete flaw detector uses the quick detection of the integrity of basic pile continuous wall with ultrasonic penetration method.

SKU: EMSSFD-234 Category:

Overview

Emissions and Stack concrete flaw detector uses the quick detection of the integrity of basic pile continuous wall with ultrasonic penetration method. and Testing depth of concrete fractures, quality of combined surface thickness of surface damage layer internal defect of steel pipe concrete, empty areas, and cellular empty with Ultrasonic Method and Testing of wells using a Single Hole, single Emitter, double Receiver Method, and the mechanical properties of nonmetal materials such as Geological survey, rock, concrete.

 

Technical Specifications

Master Unit Built A 8 industrial motherboard
Display 5.7 in, high brightness, TFT colour LCD capacitive screen
Operation Method Button + touch screen
Storage Method Built in electronic hard drive (≥ 4 GB) + large capacity U disk
Acoustic Accuracy 0.025 μs
Acoustic Range ± 1677700 μs
Dynamic Range 154 dB
Bandwidth 3 KHz to 450 KHz
Receiving Sensitivity ≤ 10 μ V
Gain Accuracy 0.5 dB
Emission Voltage 65 V, 250 V ,500 V ,1000 V
Communication Interface USB, Mini USB, Wi Fi, Blue tooth
Working Time ≥ 5 Hrs
Power Supply Built in lithium battery
 Voltage 220 V AC / DC
 Humidity < 90 % RH
Temperature 14 °F to 104 °F (-10 ℃ to + 40 ℃)
Host Dimensions 8.27 in x 5.87 in x 2.36 in (210 mm × 149 mm × 60 mm)
Host Weight 3.00 Ib (1.36 Kg) (with built in battery)

Reviews

There are no reviews yet.

Be the first to review “Emissions and Stack Concrete Flaw Detector”

Your email address will not be published. Required fields are marked *

Scroll to Top