Emissions and Stack Concrete Flaw Tester

The Concrete Flaw Tester has a frequency range of 0.4 MHz to 20 MHz, a dynamic range of ≥32dB, and a working temperature of -4 °F to 158 °F.

SKU: EMSCFD-210 Category:

Features

  • Automated gain, Peak Hold and Peak Memory
  • Automated display precise flaw location (Depth d, level p, distance s, amplitude, sz dB)
  • Ten independence setups, any criterion can be input freely, we can work in the scene without test block
  • Big memory of 300 A graph and 30000 thickness value
  • Gate and DAC alarm; Acoustic-Optical alarm
  • RS232 port, communication with pc is easy
  • The embedded software can be online updated
  • Li battery, continue working time up to 7 hours
  • Other assistant function
  • Display freeze
  • Automated echo degree
  • Angles and K-value
  • Lock and unlock function of system parameters
  • Dormancy and screen savers
  • Electronic clock calendar
  • Two gates setting and alarm indication
  • High-speed capture and very low noise
  • DAC, AVG; Solid metal housing (IP65)
  • Provides high contrast viewing of the waveform from bright, direct sunlight to complete darkness and easy to read from all angles
  • Powerful pc software and reports can be exported to excel

 

Technical Specifications

Range Of Scanning (mm) Range of scanning (mm): 0.1 in to 2362.20 in (2.5 mm to 60000 mm) (Steel Longitudinal wave)
Steps: 2.5, 5, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100, 150, 200, 250, 300, 350, 400, 50, 500, 600, 700, 800, 900, 1000, 2000, 3000, 4000, 5000, 6000
Adjusting step: 0.004 in (0.1 mm) (0.1 in to 3.93 in (2.5 mm to 99.9 mm)), 0.04 in (1 mm) (3.93 in to 393.70 in (100 mm to 10000 mm))
D-delay (ms) D-delay (ms): -20 to +3400
Steps: -20, -10,0.0, 10, 20, 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3400.
Adjusting steps: 0.1(-20 ms to 999.9 ms), 1(1000 ms to 3400 ms)
P-delay (ms) P-delay:0.0 to 99.99
Adjusting steps: 0.01
MTLVEL(m/s) MTLVEL:1000 to 9999
7 fixed levels: 2260, 2730, 3080, 3230, 4700, 5920, 6300
Adjusting steps:1
Working Mode Single probe (receiving and sending), double probe (one for receiving and another for sending), transmission (transmission probe)
Frequency Range (MHz) 0.4 to 20
Gain Adjustment (dB) 0 to 110 Adjusting step: 0.0,0.2,0.5,1,2,6,12
Reject 0% to 80% of screen height, step: 1%
Vertical Linear Error Vertical linear error is not more than 3%
Horizontal Linear Error Not more than 0.2% in the scanning range
Sensitivity Leavings ≥62 dB
Dynamic Range ≥32 dB
Alarm Three modes, i.e., forbidden wave, loss wave and auto
Monitoring Door 2, expressed by bold transverse line, whose start, width and height are adjustable.
Adjusting range of start (mm): horizontal pixel 0 in to 8.19 in (0 mm to 208 mm), the displayed value is relative with the scanning range.
Step: value in mm corresponding to a pixel (relative with the scanning range)
Adjusting range of width (mm): horizontal pixel 0.16 in to 8.35 in (4 mm to 212 mm), the displayed value is relative with the scanning range.
Step: value in mm corresponding to a pixel (relative with the scanning range)
Adjusting range of height: 2% to 90% of vertical graduation
Step graduation: 1%
Display Display: high-brightness lattice
A-Scan Display Area Full screen or local
A-Scan display freezing and de-freezing A-Scan filling
Data Save 300 A-Scan images (including setting of instrument)
30000 values of thickness (300 sets)
Standard Communication Interface With PC RS 232
Measuring Unit Mm/in
Battery Li battery 4 × 3.6 V 4800 mAh
Power Adaptor Input 100 V to 240 V/50 Hz to 60 Hz
Output 9 V to 12 V DC/1.5 A
Working Humidity 20% to 90%
Port Type BNC
Working Temperature -4 °F to 158 °F (-20 ℃ to 70 ℃)
Dimension (mm) 9.45 in × 7.09 in × 1.97 in (240 mm × 180 mm × 50 mm)
Weight (kg) 3.97 lbs. (1.8 kg)